Recommended Products

  • 12V 1040mm x 524mm Demista Heated Bathroom Mirror 7540 100W
    Image of 230V 1040mm x 524mm Demista Heated Bathroom Mirror 7540 100W
    Regular price
    £123.71
    Sale price
    £123.71
    Regular price
    £238.37
    Unit price
    per 
    Sold out
  • 12V 1550mm x 524mm Demista Heated Bathroom Mirror 7550 150W
    Image of 230V 1550mm x 524mm Demista Heated Bathroom Mirror 7550 150W
    Regular price
    £190.65
    Sale price
    £190.65
    Regular price
    £367.64
    Unit price
    per 
    Sold out
  • 12V 274mm x 150mm Demista Heated Bathroom Mirror 7505 7W
    Image of 230V 274mm x 150mm Demista Heated Bathroom Mirror  7505 7W
    Regular price
    £41.18
    Sale price
    £41.18
    Regular price
    £83.43
    Unit price
    per 
    Sold out
  • 12V 274mm x 265mm Demista Heated Bathroom Mirror 7510 15W
    Image of 230V 274mm x 265mm Demista Heated Bathroom Mirror 7510 15W
    Regular price
    £44.83
    Sale price
    £44.83
    Regular price
    £96.70
    Unit price
    per 
    Sold out

YOUR CART

Estimated timescale to despatch underfloor heating is 1 working day, for other products it's 3-5 working days. Underfloor heating mats and cables have FREE NEXT WORKING DAY DELIVERY WHEN ORDERED BEFORE 4.30PM

Common Mistakes When Installing Electric Underfloor Heating

The Most Common Mistakes When Installing Electric Underfloor Heating (and How to Avoid Them)

Electric underfloor heating (EUFH) systems are growing in popularity due to their luxurious comfort, energy efficiency, and space-saving benefits. However, the performance and longevity of your heating system depend heavily on a proper installation. Even seemingly small mistakes can result in inefficiency, safety hazards, and even complete system failure.

In this comprehensive guide, we’ll highlight the most common installation mistakes for EUFH, and how to avoid them. Whether you’re a seasoned installer or a DIY enthusiast, understanding these pitfalls will ensure a trouble-free installation and optimal performance for years to come.

Failing to Properly Plan the Layout

One of the most significant and yet often overlooked mistakes is failing to plan the layout of the electric heating system. EUFH mats or cables need to be positioned correctly to ensure even heat distribution and to avoid wasted energy.

How to Avoid This:

- Create a Detailed Layout Plan: Draw out the exact position of heating mats or cables, making sure to keep clear of fixed furniture (e.g., kitchen islands or bathroom cabinets). This will prevent the system from overheating under items that can’t dissipate heat.

- Map Out the Thermostat Placement: Consider where the thermostat and sensors will be positioned. They should be easily accessible and placed away from other heat sources, such as radiators or hot water pipes, which could interfere with temperature readings.

- Leave Adequate Fitting Space: Ensure there is a gap around the edges of the room, often referred to as fitting space. This gap prevents the heating cables from being too close to walls or fixtures, allowing for better thermal expansion and preventing overheating.

Neglecting to Install Insulation Boards

Skipping the use of insulation boards under the heating system is a critical mistake. Insulation ensures that the heat generated is directed upwards into the room rather than lost into the subfloor, making the system far more efficient.

How to Avoid This:

- Always Use High-Quality Insulation Boards: Choose boards designed specifically for underfloor heating installations, which provide effective thermal resistance. While they might increase initial costs, they significantly reduce running costs and improve heat-up times.

- Match Insulation Type to Subfloor: For concrete floors, thicker insulation boards are necessary, whereas for timber floors, a thinner type might suffice. This helps achieve optimal efficiency without excessively affecting floor height.

Incorrect Placement of Floor Sensors

The floor sensor is crucial for monitoring and controlling the temperature of your electric underfloor heating. Placing it incorrectly can lead to an inaccurate reading, causing the system to overheat or underheat.

How to Avoid This:

- Place the Sensor Equidistant Between Heating Cables: The floor sensor should not be placed too close to any heating element, as this will result in misleadingly high readings. Instead, position it equidistant between two cable runs. If this mistake is made, and the floor finish is already installed preventing repositioning of the sensor, normally up to 5°C of calibration can be used within the controller to help with this issue. 

- Consider using a Conduit Tube for the Sensor: Installing the sensor in a flexible conduit tube allows for easy replacement if the sensor fails, avoiding the need to rip up the floor.

- Keep Away from External Heat Sources: Avoid positioning the sensor near other heat sources, such as hot water pipes or direct sunlight, as this can cause inaccurate temperature readings and disrupt the system’s effectiveness.

Overlapping or Crossing Heating Cables

Heating cables should never overlap or cross each other. Overlapping creates hot spots, which can cause the cable to overheat, leading to potential system failure or even fire hazards.

How to Avoid This:

- Maintain Proper Spacing: Follow the manufacturer’s recommended spacing for the heating cables. Typically, spacing should be consistent throughout the entire area to ensure uniform heat distribution.

- Use Fixing Strips or Tape: Fixing strips or double-sided tape will help keep cables in place during installation, reducing the risk of overlapping or shifting.

Incorrect Handling of Cold-Tail Connections and End Terminations

The cold-tail connection and end termination are critical parts of the system where electrical connections are made. Installing these parts incorrectly or leaving them exposed can lead to system failures or dangerous overheating.

How to Avoid This:

- Install in Cementitious Media: Both the cold-tail connection and end termination should be fully encased in a cementitious medium, such as tile adhesive, screed, or self-levelling compound. This protects the joints and connections from potential damage and heat build-up.

- Avoid Leaving Connections Exposed: Never install these parts in the open air or beneath fixtures and fittings, as they are not designed to be exposed. If left unprotected, they are prone to failure and could cause uneven heating.

- Do Not Tape Over the Connections: Taping over connections might seem like a quick fix, but it can trap heat and cause localized overheating. Always use the appropriate cementitious material to encapsulate these parts.

Not Testing the System Before Laying the Flooring

Installing the final floor covering before testing the heating system is a major mistake. If there’s an issue with the cables, sensors, or connections, it becomes much harder (and more costly) to resolve once the floor is in place.

How to Avoid This:

- Conduct Multiple Tests Throughout Installation:

- Continuity Test: Use a digital multimeter to perform a continuity test to check for breaks or faults in the cable.

- Insulation Resistance Test: If you have a multi-function tester, measure the insulation resistance to ensure that there’s no leakage from the heating cable.

- Final System Test: Once the cables are laid and connected, perform a full system test before covering with tiles or other flooring materials. The cables must not be energised for any longer than a few minutes without them being encapsulated in levelling compound or tile adhesive. 

Understanding Permanent Changes

One of the most critical aspects of installing electric underfloor heating is recognising that some changes are permanent and can be difficult to reverse. Once the tiles are laid or the levelling compound is poured, rectifying any mistakes or issues becomes significantly more complicated and costly.

To avoid the headache of post-installation problems, it's essential to double-check everything before proceeding. Always confirm that all aspects of the installation meet the necessary guidelines and requirements. If you have any uncertainties about the installation process, don’t hesitate to reach out to us.

How to Ensure a Successful Installation:

- Consult Before You Proceed: If you have any doubts or questions about the installation, contact us. We are here to assist you with any concerns and provide expert guidance.

- Document the Installation: Before laying any tiles or pouring any levelling compound, send us a photo or video of your installation setup. This documentation will help us identify any potential issues and provide tailored advice to ensure everything is in order before any tiles are laid or the levelling compound is poured.

Taking these precautions will save you time, money, and frustration in the long run, ensuring that your electric underfloor heating system is installed correctly and operates effectively for years to come.

Using the Wrong Adhesive or Levelling Compound

Using unsuitable adhesives or levelling compounds can damage the heating system or reduce its efficiency. Cement-based adhesives or levelling compounds without flexibility can crack or cause damage to the cables when heated.

How to Avoid This:

- Always Use Flexible Adhesives and Compounds: Choose adhesives and levelling compounds specifically designed for underfloor heating installations. They have the necessary flexibility to expand and contract with the heating cycles without causing damage. These are normally marked as flexible, latex, or flexible fibre reinforced. Also, closely follow the guidlines on watering, over-watering compounds that are to be used with underfloor heating systems can cause a major issue with cracking and flaking of the compound. If in doubt employ a professional to level the floor after installing the heating mats. 

- Check Manufacturer Guidelines: Read through the manufacturer’s instructions carefully to see what materials are recommended. Incompatible materials can void warranties or lead to early system failures.

Fitting Tiles Using the Dot-and-Dab Technique

The dot-and-dab tiling method leaves gaps under the tiles, which can result in air pockets around the heating cable. This leads to uneven heating, hot spots, and potential cable burn-out.

How to Avoid This:

- Use a Solid Bed of Tile Adhesive: Ensure that the heating cables are fully encapsulated in tile adhesive or other cementitious media. Apply the adhesive evenly with a notched trowel to eliminate any air pockets.

- Check for Full Coverage: Press down firmly on the tiles to ensure complete coverage. Any gaps or voids left around the cable can cause overheating and system failure.

Turning on the System Before the Adhesive or Screed Has Fully Cured

Switching on the system too soon can cause the adhesive, screed, or cement to crack and compromise the installation. The heating system should never be used to speed up the drying process.

How to Avoid This:

- Wait Until the Material is Fully Cured: Follow the manufacturer’s guidelines for the specific curing time of the adhesive or screed used. This can range from a few days to several weeks, depending on the product and the environmental conditions.

- Avoid Using the Heating System to Dry Out Wet Trades: Using the system to dry out screed or adhesive can cause it to cure unevenly, leading to cracks and damage to the floor finish.

Ignoring Manufacturer Instructions

It might seem obvious, but many issues arise from simply ignoring the installation guidelines provided by the manufacturer. These instructions are tailored to the specific product and are designed to ensure a safe and effective installation.

How to Avoid This:

- Follow Every Step in the Manufacturer’s Guide: Take the time to read through and understand the instructions. If you’re unsure about any aspect, contact the manufacturer or consult with a professional.

- Keep a Copy of the Instructions Handy: Ensure that all installers have access to the instructions during the installation process to prevent any misunderstandings or shortcuts.

Conclusion: Ensuring a Smooth EUFH Installation

Installing electric underfloor heating can be a straightforward and rewarding process, but only if approached with careful planning and attention to detail. Avoiding these common mistakes will not only ensure a safe and efficient heating system but also save you time, money, and frustration in the long run.

If you’re unsure about any aspect of your EUFH installation, it’s always best to consult with a professional or reach out to us. Remember, a little preparation and understanding of these common pitfalls can make all the difference in achieving a perfectly heated floor that lasts for years.

Need more advice or have any specific installation questions? Use our contact form, email us directly or get in touch by phone—we’re here to help!